Cray X Active Back Exoskeleton: Erector Spinae EMG Across 11 Support Levels
Walter T., Stutzig N., Siebert T.
University of Stuttgart · 2023 · Germany
Dose-response evaluation of the Cray X generation-4 active back exoskeleton: 14 participants stoop-lifted a 15 kg box at support levels from 0 to 100% in 10% steps plus a no-device condition while bilateral erector spinae EMG was recorded (Frontiers in Bioengineering and Biotechnology, 2023). Rare graded-assistance dataset; raw data available from the authors without undue reservation.
Details
- Subjects
- n = 14 · 3F / 11M · 22.3 ± 1.1
- Setting
- Laboratory (controlled or simulated)
- Protocol / load
- Stoop lifting of a 15 kg box (40 x 30 x 22 cm) at 11 graded support levels
- Equipment
- BTS FREEEMG 1000 bilateral erector spinae EMG (1000 Hz); 30 Hz video for phase demarcation; Borg RPE
- Sampling
- emg 1000 Hz · video 30 Hz
- License
- Raw data from the authors without undue reservation
- Keywords
- exoskeleton, back, active-exoskeleton, lifting, support-levels, semg
- Added to catalog
- 2026-09-01
Publications
- Walter T., Stutzig N., Siebert T. (2023). Active exoskeleton reduces erector spinae muscle activity during lifting. Front. Bioeng. Biotechnol. 11:1143926~22% erector spinae EMG reduction at maximum support vs. no exoskeleton.
Exoskeleton
- Record type
- Device evaluation
- Device(s)
- Cray X (German Bionic)
- Body region
- Back
- Actuation
- Active
- Study design
- Support levels 0-100% in 10% steps plus no-exoskeleton condition, stoop lifting, within-subject
- Outcomes
- Muscle activity (EMG), Subjective ratings
This record is part of the exoskeleton collection.
Cite
Cite the dataset as its authors request (check the source page for an official citation); this BibTeX is a convenience starting point.
@misc{walter-crayx-support-levels,
author = {Walter, T. and Stutzig, N. and Siebert, T.},
title = {{Cray X Active Back Exoskeleton: Erector Spinae EMG Across 11 Support Levels}},
year = {2023},
url = {https://doi.org/10.3389/fbioe.2023.1143926},
}